YOKE DA-007 – DA Welded Master Link Assembly, DNV certified

Welded master link assembly with DNV certification (offshore), design factor 5:1, working load limit 4.1–45 tonnes.

Official representative in Romania

9 codes available · WLL 4.1–45 t

Choose the code from the table

Tick the codes and quantities you need in the table, then send your quote request.

Request a quote
SKU: DA-007 Categories: ,

Codes and dimensions – YOKE DA-007

Tick the codes you need, choose the quantity and add them to your quote request.

YOKE DA-007 dimension drawing
Dimensions A, B, D… in the table, in mm
Select Item no. Assembled with WLL at β 0–45° Proof load Single hook DIN 15401 no. Dimensions (mm) Qty
t kN A a B b D d
DA-007-16 FD-161+2 FD-131 4.1 100 4 140 90 70 50 16 13
DA-007-22 FD-222+2 FD-191 8.9 218 6 162 140 90 70 22 19
DA-007-25 FD-251+2 FD-19 8.9 218 16 275 160 145 90 25 19
DA-007-28 FD-28+2 FD-22 12.9 316 16 275 180 145 100 28 22
DA-007-32 FD-32+2 FD-25 17 417 16 275 210 145 115 32 25
DA-007-36 FD-361+2 FD-281 23.6 578 16 275 190 145 100 36 28
DA-007-40 FD-40+2 FD-32 28.1 688 20 300 275 160 145 40 32
DA-007-45 FD-45+2 FD-36 38.3 938 25 340 285 180 155 45 36
DA-007-50 FD-50+2 FD-401 45 1103 32 350 260 195 130 50 40

Technical data: YOKE Industrial Corp. WLL values apply to the design factor stated by the manufacturer.

The DA-007 is an assembly of a welded master link and two secondary links (for example FD-16 with 2 × FD-13), with DNV certification (offshore). It is made of welded quenched and tempered alloy steel, tested and manufactured in accordance with DNV-ST-E271, DNV-ST-E273 and EN 1677-4, with a design factor of 5:1. It covers working load limits (WLL) of 4.1–45 tonnes at a β angle of 0–45°, and impact resistance is verified by Charpy testing (42 joules at -40°C for the normal section, 27 joules for the welded section).

Features

  • Welded alloy steel, quenched and tempered.
  • Tested and manufactured in accordance with DNV-ST-E271, DNV-ST-E273 and EN 1677-4.
  • Charpy tested in accordance with DNV-ST-E271.
  • Certified by DNV-ST-E271 and DNV-ST-E273.
  • Design factor 5:1.
  • Proof load tested to 2.5 times the Working Load Limit (WLL).
  • Fatigue rated to 20,000 cycles at 1.5 times the Working Load Limit (WLL).
  • Magnaflux crack detection is performed 100% on each batch.
  • Charpy test of 42 joules (31 ft-lb) at -40°C (-40°F) for normal section.
  • Charpy test of 27 joules (20 ft-lb) at -40°C (-40°F) for welded section.

ELCAR is the official YOKE representative in Romania. Choose the codes in the table above and send your quote request.

Areas of activity

, , , , ,

Reviews

There are no reviews yet.

Be the first to review “YOKE DA-007 – DA Welded Master Link Assembly, DNV certified”